Did you ever wonder, what keeps your Oncology practice running? Is it the perfect oncology billing
practices or accurate coding? Well, to be genuine, the answer is both! But, if at all you would like
to choose the most important reasons for oncology denials, it would be inaccurate oncology coding!
Better be aware!
Oncology coding is preferred to be the bedrock for oncology specialty practices. If the coding goes
wrong, then you are sure of losing revenue payments. You must be prepared for it! While oncology
coding depends on accurate codes, revenue payments depend on correct coding practices. It’s definite
that you’re heading towards success.
It’s evident that oncology drugs are very expensive and healthcare professionals can’t afford to
lose revenue if billing and coding goes wrong. Improper and inaccurate oncology coding practices
will have major impact on healthcare professionals’ revenue cycle management process.
Keep in mind that every procedure should be billed from the beginning of treatment course and again
when new or additional treatment or equipment is required.
CPT codes used in Oncology coding procedures:
CPT code 77332:
The above CPT code is used for simple treatment devices, designs as well as construction which
include very simple port blocks that also takes in one or more hand positioned pre-maid blocks,
simple pre-fabricated bolus which has the capacity of shaping for individual patient or individual
jaw motion or asymmetrical collimation.
CPT code 77333:
The above CPT code is used for intermediate treatment devices, designs as well as construction which
include multiple port blocks that also take in three or more blocks or pre-made blocks such as
corner pelvis blocks, beam splitter blocks, midline spinal cord blocks, stents, bite blocks, and
special multi use bolus.
CPT code 77334:
The above code is used for complex treatment devices, designs as well as construction which include
customized, single used bolus such as wax molds confirmed to certain peculiar body parts along with
customized blocks with low alloy, customized compensators, wedges, molds and casts also customized
immobilization devices and eye shields.
CPT code 77336:
The above code is used for continuous medical radiation physics consultation that includes the
assessment of treatment parameters, assurance of quality in delivering perfect dosage, review of
patient documentation in support of radiation oncologist reported for a week of therapy that
includes once in every five treatments provided.
CPT code 77370:
The above code is used for separate and special radiation physics consultation services that include
when a problem is addressed or when a special situation arrives during radiation therapy. This
particular code requires a complete and detailed report on the problem describing it and endorsing
to requested physician.
CPT code 77387:
The above code is used for Guidance for Localization of target volume for delivering radiation
treatment which includes intrafraction tracking. It should only be used by OPPS.
Important Note: Radiation treatment procedures and their delivery codes are frequently reported once
per treatment session and additionally, these codes can recognize only the technical component but
doesn’t contain physician work.
The professional component contains only treatment management codes with only professional
component. Insurance companies agree to pay for these terms and conditions based under CPT codes
77401-77416 for delivering radiation treatment.
CPT code 77401:
The above code is used for radiation treatment delivery, superficial /orthovoltage for a day. Never
report clinical treatment planning – 77261,77262, and 77263, treatment devices with codes-
77332,77333 and 77334, For Isodose – 77306 and 77307,physics consultation- 77336, treatment
management- 77427,77431 and 77470 with 77401.
CPT code 77407:
The above code is used for intermediate treatment delivery that requires any of these below are met
but none of these complex criteria aren’t met. The criteria consist of two treatment areas, three or
more ports, three or more single blocks. Remember, this code is only used by OPPS.
CPT code 77412:
The above code is used for complex treatment delivery which requires if any of these criteria are
met. For which three or more separate treatment areas, custom blocking, tangential blocks, sedges,
rotational beam or tissue compensation which does not meet any guidelines and this code is only used
by OPPS.
CPT code 77295:
The above code is used in order to report three dimensional radiotherapy plan that includes dose
value histogram, while this code also includes procedures those performed in coplanar therapy beams.
Hence, the below codes are used and aren’t allowed to bill separately on the same date. Those codes
are- 77280, 77285 and 77290.
CPT code 77300:
The above code is used for basic radiation dosimetry, calculation, central axis depth, TDF, NSD, gap
calculation, off axis factor, tissue homogeneity factors, according to the course of treatment when
only prescribed by particular healthcare professional.
Any changes in patient’s weight and birth, at the time of radiation treatment might end up in
dosimetry recalculation. This particular procedure is not required to perform routinely each time of
the treatment.
Tips to Submit Proper Documentation:
Never attach the patient details or treatment information to the original claim.
Ensure if detailed information, itemization and supporting documentation are billed for all services
.
Mention clean documentation of history of treatment involved.
Documentation of healthcare professional’s involvement.
Hope you got the information on Oncology coding. For any suggestions, please comment below. For any
queries related to healthcare, please subscribe to our blog. Please do watch and read the other
blogs available on our website. Don’t forget to follow us on Facebook, Instagram and LinkedIn.
